FMSXY Stepping Motor 2D Scanning Stage
Feinixs developed the integrated stepping 2D stage. The controller can be built in. Excellent bi-directional repeatability and micro-stepping capability. The structure is small and easy to be integrated. Can be equipped with standard FMC01 series controller, and also provide SDK to customers for secondary development.
The range of travel: 20mm(XY),25mm(XY);
Integrated X&Y-axis design;
A controller built-in is optioned;
Ultra-silent rotary stage:Suitable for laboratory environments and industrial sites with high performance requirements;
Free standard edition SDK:Multiple development languages are supported in the Window or Linux environment;Such as C/C++、C#、Matlab、LabVIEW etc;
The controller:Realize arc interpolation, linear interpolation, position memory to lead into arbitrary-graphics;
Option:Bus control of EtherCAT
APPLICATION FIELDS
2D Scan、 Testing Equipment、 Microscope Stage
TYPICAL ASSEMBLY

It can be flexibly combined into multi-axis motion system,Contact for more information
ERROR CURVE

|
Model |
FMSXY100-20-20 |
FMSXY120-25-25 |
|
Travel(mm) |
20(XY) |
25(XY) |
|
Load Capacity(Kg)[1] |
2 |
2 |
|
Resolution(μm) |
0.625 |
0.625 |
|
Min.Incremental Motion(μm)[2] |
1 |
1 |
|
Undirection Repeatability[3]/Guaranteed(μm)[4] |
±2 or 4 |
±2 or 4 |
|
Undirection Repeatability/Typical(μm) |
±1 or 2 |
±1 or 2 |
|
Bi-Directional Repeatability/Guaranteed(μm) |
±4 or 8 |
±4 or 8 |
|
Bi-Directional Repeatability/Typical(μm) |
±2 or 4 |
±2 or 4 |
|
Accuracy[3]/Guaranteed(μm) |
±20 or 40 |
±20 or 40 |
|
Accuracy/Typical(μm) |
±10 or 20 |
±10 or 20 |
|
Max.Speed(mm/s)[5] |
5 |
5 |
|
Straightness(μm) |
20 |
20 |
|
Flatness(μm) |
20 |
20 |
|
Yaw(arcsec) |
35 |
30 |
|
Pitch(arcsec) |
35 |
30 |
|
Weight(kg) |
1.2 |
2.3 |
Remark:
[1]:The vertical-load of the center under the Horizontal-placement。
[2]:The minimum motion increment is not the same as resolution,It means the minimum amount that a motion system can move in a continuous, stable situation. Generally, The resolution of the system is much smaller than the minimum motion increment. In consideration of the influence of transmission structure and the system error of the encoder, To compared with the linear motor displacement stages and the stepping motor displacement stages, The minimum motion increment of the linear motor displacement stages is more closer to the resolution.
[3]:The accuracy measurement data is the data measured by the laser interferometer when the platform is placed horizontally. The measurement standard reference to GB/T17421-2000
[4]:The difference between typical values and guaranteed values is described in the Technical Guide.
[5]:The maximum speed is typical values , On the basis of the difference of the load and the controller it would be Make a difference