FMSA Stepping Motor Inclination Stages
In some teaching and posture adjustment applications, some simple positioning of the inclinometer stages is required. For this reason, Feinixs developed two sets of FMSA series inclination stages. Each set can be superimposed to form a concentric 2D inclination stages.
Range of angular rotation:±10°、±15°
In paired design, The inclination axes converge on the central point;
Free standard edition SDK:Multiple development languages are supported in the Window or Linux environment;Such as C/C++、C#、Matlab、LabVIEW etc;
APPLICATION FIELDS
X-ray、Device Tuning、Laser Target、Optical Machine、Teaching Instrument
TYPICAL ASSEMBLY

It can be flexibly combined into multi-axis motion system,Contact for more information
|
Model |
FMSA65-10 |
FMSA65-15 |
FMSA120-10 |
FMSA120-15 |
|
Travel(°) |
±10 |
±15 |
±10 |
±15 |
|
Load Capacity(Kg)[1] |
4 |
4 |
10 |
10 |
|
Resolution(°) |
0.00032 |
0.00045 |
0.0005357 |
0.00075 |
|
Min.Incremental Motion(°)[2] |
0.005 |
0.005 |
0.005 |
0.005 |
|
Undirection Repeatability[3]/Guaranteed(°)[4] |
±0.005 or 0.01 |
±0.005 or 0.01 |
±0.005 or 0.01 |
±0.005 or 0.01 |
|
Undirection Repeatability/Typical(°) |
±0.003 or 0.006 |
±0.003 or 0.006 |
±0.003 or 0.006 |
±0.003 or 0.006 |
|
Bi-Directional Repeatability/Guaranteed(°) |
±0.01 or 0.02 |
±0.01 or 0.02 |
±0.01 or 0.02 |
±0.01 or 0.02 |
|
Bi-Directional Repeatability/Typical(°) |
±0.005 or 0.01 |
±0.005 or 0.01 |
±0.005 or 0.01 |
±0.005 or 0.01 |
|
Accuracy[3]/Guaranteed(°) |
±0.05 or 0.1 |
±0.05 or 0.1 |
±0.05 or 0.1 |
±0.05 or 0.1 |
|
Accuracy/Typical(°) |
±0.03 or 0.06 |
±0.03 or 0.06 |
±0.03 or 0.06 |
±0.03 or 0.06 |
|
Max.Speed(°/s)[5] |
5 |
7 |
10 |
15 |
|
Weight(kg) |
0.6 |
0.6 |
4 |
3.5 |
Remark:
[1]:The vertical-load of the center under the Horizontal-placement。
[2]:The minimum motion increment is not the same as resolution,It means the minimum amount that a motion system can move in a continuous, stable situation. Generally, The resolution of the system is much smaller than the minimum motion increment. In consideration of the influence of transmission structure and the system error of the encoder, To compared with the linear motor displacement stagess and the stepping motor displacement stagess, The minimum motion increment of the linear motor displacement stagess is more closer to the resolution.
[3]:The accuracy measurement data is the data measured by the laser interferometer when the platform is placed horizontally. The measurement standard reference to GB/T17421-2000
[4]:The difference between typical values and guaranteed values is described in the Technical Guide.
[5]:The maximum speed is typical values , On the basis of the difference of the load and the controller it would be Make a difference.