Language
  1. CH
  2. EN
Search
(0)
Home Product Motorized Translation Stage FMS120 High Precision Stepper Motor Stages
FMS120 High Precision Stepper Motor Stages

$1430 Stock:3

Product Consultation

Scan the QR code for consultation

Or make a phone call:

028-8586 4663

Send email:

info@feinixs.com
Product Details

FMS120 High Precision Stepper Motor Stages

 

In order to build optical experiment and teaching demonstration platform, Feinixs developed FMS120 series stepper motor Stages, which is equipped with Taiwan Hiwin H-class guide rail and Shanghai MOONS motor, making the product cost-effective. Large table is suitable for large samples, and also  can be  the bottom axis of multi-axis system.

 

The range of travel:50mm、100mm、150mm;

Solid frame design:Ensures XY-shaft assembly reliably with a maximum stroke of 300mm×300mm;

Free standard edition SDK:Multiple development languages are supported in the Window or Linux environment;Such as C/C++、C#、Matlab、LabVIEW etc;

 

APPLICATION  FIELDS

 

Optical Experiment 、Teaching Instrument 、Demonstration Experiment 、 Automatic Control

 

TYPICAL ASSEMBLY

 

It can be flexibly combined into multi-axis motion system,Contact for more information

 

ERROR CURVE

 

Product parameters

Model

FMS120-100

FMS120-200

FMS120-300

Travel(mm)

100

200

300

Load Capacity(Kg)[1]

20

20

20

Resolution(μm)

2.5

2.5

2.5

Min.Incremental Motion(μm)[2]

3

3

3

Undirection Repeatability[3]/Guaranteed(μm)[4]

±1 or 2

±2 or 4

±3 or 6

Undirection Repeatability/Typical(μm)

±0.5 or 1

±1 or 2

±2 or 4

Bi-Directional Repeatability/Guaranteed(μm)

±3 or 6

±3 or 6

±4 or 8

Bi-Directional Repeatability/Typical(μm)

±2 or 4

±2 or 4

±3 or 6

Accuracy[3]/Guaranteed(μm)

±12 or 24

±15 or 30

±20 or 40

Accuracy/Typical(μm)

±6 or 12

±8 or 16

±10 or 20

Max.Speed(mm/s)[5]

40

40

40

Straightness(μm)

12

15

20

Flatness(μm)

12

15

20

Yaw(arcsec)

30

40

50

Pitch(arcsec)

30

40

50

Weight(kg)

4.5

5.6

6

 

Remark:

[1]:The vertical-load of the center under the Horizontal-placement。

[2]:The  minimum motion increment is not the same as resolution,It means the minimum amount that a motion system can move in a continuous, stable situation. Generally, The resolution of the system is much smaller than the minimum motion increment. In consideration of the influence of transmission structure and the system error of the encoder, To compared with the linear motor Motorized drive Stages and the stepping motor Motorized drive Stages, The minimum motion increment of the linear motor Motorized drive Stages is more closer to the resolution.

[3]:The accuracy measurement data is the data measured by the laser interferometer when the platform is placed horizontally. The measurement standard reference to GB/T17421-2000

[4]:The difference between typical values and guaranteed values is described in the Technical Guide.

[5]:The maximum speed is typical values , on the basis of the difference of the load and the controller it would be Make a difference.

Product size

tips