Language
  1. CH
  2. EN
Search
(0)
Home Product Motorized Vacuum Translation Stage FMS80V Vacuum Motor High-precision Stages
FMS80V Vacuum Motor High-precision Stages

$5000 Stock:5

Product Consultation

Scan the QR code for consultation

Or make a phone call:

028-8586 4663

Send email:

info@feinixs.com
Product Details

FMS80V Vacuum Motor High-precision Stages

 

On the basis of FMS80 series, we designed FMS80V series Vacuum Stepper Motor Stages.  The FMS80V is widely used in vacuum applications and can maintain high accuracy in -196 ~ + 250℃ high/ low temperature environments, various radiation environments and vacuum 10-7~10-3Pa environments.

 

The range of travel:50mm、100mm、150mm;

Solid frame design:Ensures XY-shaft assembly reliably with a maximum stroke of 150mm×150mm;

Vacuum environment use: series products can be used in vacuum;

Free standard edition SDK:Multiple development languages are supported in the Window or Linux environment;Such as C/C++、C#、Matlab、LabVIEW etc;

 

APPLICATION  FIELDS

 

Laser Target、  Device Tuning、  High Energy Physics

 

TYPICAL ASSEMBLY

 

It can be flexibly combined into multi-axis motion system,Contact for more information

 

ERROR CURVE

 

Product parameters

Model

FMS80V-50

FMS80V-100

FMS80V-150

Travel(mm)

50

100

150

Load Capacity(Kg)[1]

10

10

10

Resolution(μm)

0.625

0.625

0.625

Min.Incremental Motion(μm)[2]

1

1

1

Undirection Repeatability[3]/Guaranteed(μm)[4]

±1 or 2

±1 or 2

±1 or 2

Undirection Repeatability/Typical(μm)

±0.5 or 1

±0.5 or 1

±0.5 or 1

Bi-Directional Repeatability/Guaranteed(μm)

±2 or 4

±2.5 or 5

±3 or 6

Bi-Directional Repeatability/Typical(μm)

±1 or 2

±1 or 2

±1.5 or 3

Accuracy[3]/Guaranteed(μm)

±10 or 20

±12 or 24

±15 or 30

Accuracy/Typical(μm)

±5 or 10

±6 or 12

±8 or 16

Max.Speed(mm/s)[5]

10

10

10

Straightness(μm)

10

12

15

Flatness(μm)

10

12

15

Yaw(arcsec)

20

25

30

Pitch(arcsec)

20

25

30

Weight(kg)

4

4.4

4.8

 

Remark:

[1]:The vertical-load of the center under the Horizontal-placement。

[2]:The  minimum motion increment is not the same as resolution,It means the minimum amount that a motion system can move in a continuous, stable situation. Generally, The resolution of the system is much smaller than the minimum motion increment. In consideration of the influence of transmission structure and the system error of the encoder, To compared with the linear motor Motorized drive Stages and the stepping motor Motorized drive Stages, The minimum motion increment of the linear motor Motorized drive Stages is more closer to the resolution.

[3]:The accuracy measurement data is the data measured by the laser interferometer when the platform is placed horizontally. The measurement standard reference to GB/T17421-2000

[4]:The difference between typical values and guaranteed values is described in the Technical Guide.

[5]:The maximum speed is typical values , On the basis of the difference of the load and the controller it would be Make a difference.

Product size

tips